Optimum matching of ohmic loads to the photovoltaic array
Authors:Kamel Khouzam   Lucy Khouzam  Peter Groumpos
Abstract:Optimum matching of loads to the photovoltaic (PV) generator is most desirable for more accurate sizing, higher system performance and maximum utilization of the costly solar array generator. The quality of load matching depends on the PV array characteristics, the load characteristics, and the insolation profile. A matching factor is defined as the ratio of the load energy to the array maximum energy over a one day period. Optimum matching is achieved by determining the optimal array parameters with respect to the load parameters. Optimization is done using direct-search techniques. Results show that the theoretical optimum matching factor for an ohmic load is 94.34%. For an electrolytic load the matching factor could reach 99.83%. A maximum power tracker can be eliminated if optimum matching is achieved.