首页 | 本学科首页   官方微博 | 高级检索  
     

Preparation of Laminin-apatite-polymer Composites Using Metastable Calcium Phosphate Solutions
作者姓名:A Oyane  M Kasahara  N Ichinose  Y Yokoyama  M Uchida  A Ito
作者单位:Nanotechnology Research Institute National Institute of Advanced Industrial Science and Technology (AIST),Central 5 1-1-1 Higashi Tsukuba 305-8565 Japan,School of Science and Engineering Waseda University 3-4-1 Okubo Shinjuku 169-8555,Japan,School of Science and Engineering Waseda University 3-4-1 Okubo Shinjuku 169-8555,Japan,Nanotechnology Research Institute National Institute of Advanced Industrial Science and Technology (AIST),Central 5 1-1-1 Higashi Tsukuba 305-8565 Japan,Institute for Human Science and Biomedical Engineering National Institute of Advanced Industrial Science and Technology (AIST),Central 6 1-1-1 Higashi Tsukuba 305-8566 Japan,Institute for Human Science and Biomedical Engineering National Institute of Advanced Industrial Science and Technology (AIST),Central 6 1-1-1 Higashi Tsukuba 305-8566 Japan
基金项目:SupportedbyanIndustrialTechnologyResearchGrantProgramin2004fromtheNewEnergyandIndustrialTechnologyDevelopmentOrganization(NEDO)ofJapan.
摘    要:1Introduction Themostimportantrequirementofapercutaneous deviceisthepreventionofbacterialinfectionthroughtheinterfacebetweenthematerialandtheskin.Therefore,a percutaneousdevicehastoadherefirmlytoskintissueandpreventepidermaldowngrowth.Previously,Aokietalp…


Preparation of Laminin-apatite-polymer Composites Using Metastable Calcium Phosphate Solutions
A Oyane,M Kasahara,N Ichinose,Y Yokoyama,M Uchida,A Ito.Preparation of Laminin-apatite-polymer Composites Using Metastable Calcium Phosphate Solutions[J].Journal of Wuhan University of Technology. Materials Science Edition,2005,20(Z1).
Authors:A Oyane M Kasahara N Ichinose Y Yokoyama M Uchida A Ito
Affiliation:A Oyane1 M Kasahara2 N Ichinose2 Y Yokoyama1 M Uchida3 A Ito3
Abstract:A synthetic polymer with a laminin-apatite composite layer on its surface would be useful as a percutaneous device. The preparation of such a composite was attempted in the present study using poly(ethylene terephthalate) (PET) and polyethylene (PE) as the synthetic polymer. PET and PE plates and those pretreated with an oxygen plasma were alternately dipped in calcium and phosphate ion solutions, and then immersed in a metastable calcium phosphate solution supplemented with laminin (LCP solution). The PET and PE plates pretreated with an oxygen plasma formed a uniform and continuous layer of a laminin-apatite composite on their surfaces. In contrast, the PET and PE plates that had not been pretreated with an oxygen plasma did not form a continuous layer of a laminin-apatite composite on their surfaces. The hydrophilic functional groups on the PET and PE surfaces introduced by the plasma treatment were responsible for the successful laminin-apatite composite coating.
Keywords:apatite  laminin  composite  polymer  percutaneous device  calcium phosphate  coating