首页 | 本学科首页   官方微博 | 高级检索  
     


Flicker noise measurement of HF quartz resonators
Authors:Rubiola E  Groslambert J  Brunet M  Giordano V
Affiliation:Politecnico di Torino.
Abstract:Frequency flicker of quartz resonators can be derived from the measurement of S(phi) (f), i.e., the power spectrum density of phase fluctuations phi. The interferometric method appears to be the best choice to measure the phase fluctuations of the quartz resonators because of its high sensitivity in the low power conditions, which is required for this type of resonator. Combining these two ideas, we built an instrument suitable to measure the frequency flicker floor of the quartz resonators, and we measured the stability of some 10-MHB high performance resonators as a function of the dissipated power. The stability limit of our instrument, described in terms of Allan deviation sigma(y)(tau), is of some 10(-14).
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏