Calibration of LR-115 for 222Rn monitoring taking into account the plateout effect |
| |
Authors: | Da Silva A A R Yoshimura E M |
| |
Affiliation: | Laboratório de Dosimetria, Departamento de Física Nuclear, Instituto de Física da Universidade de S?o Paulo, PO Box 66318, 05315-970, S?o Paulo-SP, Brazil. almy.silva@dfn.if.usp.br |
| |
Abstract: | The dose received by people exposed to indoor radon is mainly due to radon progeny. This fact points to the establishment of techniques that access either radon and progeny together, or only radon progeny concentration. In this work a low cost and easy to use methodology is presented to determine the total indoor alpha emission concentration. It is based on passive detection using LR-115 and CR-39 detectors, taking into account the plateout effect. A calibration of LR-115 track density response was done by indoor exposure in controlled environments and dwellings, places where 222Rn and progeny concentration were measured with CR-39. The calibration factor obtained showed great dependence on the ambient condition: (0.69 +/- 0.04) cm for controlled environments and (0.43 +/- 0.03) cm for dwellings. |
| |
Keywords: | |
本文献已被 PubMed Oxford 等数据库收录! |
|