首页 | 本学科首页   官方微博 | 高级检索  
     


An analysis of the use of electrical power measurements for process control in large‐scale stirred vessels
Authors:Sven Hjorth  Lennart Karlsson  Paal Friberg  Lotte Boon
Abstract:The mechanical power that is transferred to a liquid via the shaft of an agitator is obtained from a measurement of the electrical power flowing into the electric motor within an accuracy of less than 5%. The accuracy obtained is limited by the calibration procedure. As the implementation of an electric power measurement is both simple and comparatively inexpensive, the technique is suitable for a continuous monitoring of the power used by agitators in the process industries.
Keywords:electrical power measurement  bioreactor  mechanical agitation