摘    要:介绍了4台早期国产300 MW机组汽轮机通流部分增容改造后,对凝汽器优化改造的过程,重点对凝汽器改造的背景、模式、实施情况及其经济性进行了综合分析,为同类型机组凝汽器改造提供借鉴.

关 键 词:300 MW机组  凝汽器改造  经济性分析
文章编号:1001-9529(2007)02-0049-03
修稿时间:2006-08-22

Optimization retrofits of condensers for domestically-made 300 MW units
MA Jun-chi,ZHU Yue-liang,LIU Gui-sheng. Optimization retrofits of condensers for domestically-made 300 MW units[J]. East China Electric Power, 2007, 35(2): 49-51
Authors:MA Jun-chi  ZHU Yue-liang  LIU Gui-sheng
Abstract:The process of condenser optimization retrofit for four domestically-made 300 MW units which have undergone the capacity-increasing retrofit for their steam turbine passages is recommended,with emphasis on the retrofit background,method,implementation,and economy of the retrofitted condensers.