Natural convection at an indoor glazing surface with different window blinds |
| |
Authors: | Cristian Cuevas Adelqui Fissore Nestor Fonseca |
| |
Affiliation: | a Departamento de Ingeniería Mecánica, Facultad de Ingeniería, Universidad de Concepción, Casilla 160-C, Concepción, Chile b Facultad de Ingeniería Mecánica, Universidad Tecnológica de Pereira, AA. 97 Pereira, Risaralda, Colombia |
| |
Abstract: | In the present study, an empirical model to determinate the convective heat loss, at an indoor glazing surface, is proposed. This model allows calculating the convective heat transfer coefficient and the air flow rate entering to the window cavity formed between the glazing surface and the protection device. The window blind is first studied experimentally by using a rigid paper, which is installed at four different distances from the window frame. This configuration is used as reference to determinate a global model, which is mainly composed of two correlations: one for the Nusselt number and other one for the air mass flow rate incoming to the window cavity. Then, more realistic configurations are tested: single curtains, double curtains, PVC blinds, wood blinds, Venetian blinds or polyester blinds. In general, heat transfer coefficients for these configurations are equal or higher than that obtained with a free plate. Several correlations are proposed for each configuration. |
| |
Keywords: | Window Heat transfer coefficient Blind Curtain Window |
本文献已被 ScienceDirect 等数据库收录! |
|