作者单位:国华三河发电有限责任公司,河北三河,065201
摘    要:三河发电厂二期工程2×300MW热电联产机组的烟气脱硫系统采用的是无旁路和烟塔合一技术,属于国内首家且具有示范作用。深入研究了脱硫系统无旁路运行,并对脱硫系统在运行中存在的问题及注意事项进行了探讨,为机组的安全稳定运行积累了经验。

关 键 词:脱硫  无旁路  示范作用  节能减排

Discussion on Operation of Desulphurization Unit without Bypass
Liu Hong-wei. Discussion on Operation of Desulphurization Unit without Bypass[J]. North China Electric Power, 2009, 0(2): 22-25
Authors:Liu Hong-wei
Affiliation:Liu Hong-wei ( Guohua Sanhe Power Generation Co. Ltd. , Sanhe 065201, China)
Abstract:2 × 300 MW CHP units in Sanhe Power Plant Phase II used the FGD system without bypass, which employing the technology of using cooling tower to supersede chimney. It is the first in China and plays an exemplary role. This paper studied the desulphurization system without bypass operation, and problems found during its service and precautions to be followed. All these efforts tend to accumulate experiences for safe and reliable operation of the units.