基金项目:中国石油化工股份有限公司科技开发资助项目(编号: 300023)
摘    要:对旋流板式气液分离器在3种规模、18种旋流板结构下进行了模型实验研究,考察了旋流板结构参数(径向角、仰角和叶片数量)对分离效率和压降的影响,并建立了预测分离器压降的关联式,为旋流板结构参数的确定提供了依据. 工业应用的标定结果表明分离器压降预测式是准确的,它可用于工业气液分离器的放大设计.

关 键 词:气液分离  旋流板  分离效率  压降
文章编号:1009-606X(2003)05-0390-06
修稿时间:2003年3月12日

Scale-up of Mist Swirl Separators
WEI Wei-sheng,FAN Jian-hua,BAO Xiao-jun,SHI Gang.Scale-up of Mist Swirl Separators[J].Chinese Journal of Process Engineering,2003,3(5):390-395.
Authors:WEI Wei-sheng  FAN Jian-hua  BAO Xiao-jun  SHI Gang
Abstract:Experiments were conducted in three swirl mist separators, with the internal diameters being 340, 480, and 700 mm, respectively. The separators were equipped with 18 sets of swirl vanes. The effects of superficial gas velocity and geometrical parameters, such as the elevation and the radial angle of the swirl vane, vane number, the ratio of separator body height to diameter on mist separation efficiency and pressure drop were tested. Results showed that the separation efficiency and pressure drop increased as elevation, radial angle and vane number were increased. An optimal superficial gas velocity exists in the range from 5 to 9 m/s and it decreases slightly with scale-up. The optimal distance between the swirl vane and inner exiting tube is 32%~73% of the separator diameter. The mist separator should be designed to make the separation efficiency as high as possible, with the pressure drop less than 2 kPa. The structure of the swirl vane is one of the most important parameters by which pressure drop is determined. A pressure drop correlation was established based on experimental data and theoretic analysis. A scale-up procedure was suggested for the design of industrial mist separators. Pressure drops measured from two industrial scale separators (f1.52 m and f1.90 m) were found in good agreement with the predicted values, and the separation efficiency of greater than 95% was achieved.
Keywords:mist separator  swirl vane  separation efficiency  pressure drop  
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《过程工程学报》浏览原始摘要信息
点击此处可从《过程工程学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号