首页 | 本学科首页   官方微博 | 高级检索  
     


Reduced myofibroblast differentiation on femtosecond laser treated 316LS stainless steel
Authors:Martin Oberringer  Erhan Akman  Juseok Lee  Wolfgang Metzger  Cagri Kaan Akkan  Elif Kacar  Arif Demir  Hashim Abdul-Khaliq  Norbert Pütz  Gunther Wennemuth  Tim Pohlemann  Michael Veith  Cenk Aktas
Affiliation:1. Department of Trauma, Hand and Reconstructive Surgery, Saarland University, Homburg, Germany;2. Laser Technologies Research and Application Center (LATARUM), Kocaeli University, Yeniköy/Kocaeli, Turkey;3. CVD/Biosurfaces Division, INM — Leibniz Institute for New Materials, Saarbrücken, Germany;4. BEAM Ar–Ge Optic, Laser and Spectroscopy, KOU Technopark, Kocaeli, 41275, Turkey;5. Clinic for Pediatric Cardiology, Saarland University Hospital, Homburg, Germany;6. Department of Anatomy and Cell Biology, Saarland University, Homburg, Germany
Abstract:In-stent restenosis is a common complication after stent surgery which leads to a dangerous wall narrowing of a blood vessel. Laser assisted patterning is one of the effective methods to modify the stent surface to control cell–surface interactions which play a major role in the restenosis. In this current study, 316LS stainless steel substrates are structured by focusing a femtosecond laser beam down to a spot size of 50 μm. By altering the laser induced spot density three distinct surfaces (low density (LD), medium density (MD) and high density (HD)) were prepared. While such surfaces are composed of primary microstructures, due to fast melting and re-solidification by ultra-short laser pulses, nanofeatures are also observed as secondary structures. Following a detailed surface characterization (chemical and physical properties of the surface), we used a well-established co-culture assay of human microvascular endothelial cells and human fibroblasts to check the cell compatibility of the prepared surfaces. The surfaces were analyzed in terms of cell adherence, proliferation, cell morphology and the differentiation of the fibroblast into the myofibroblast, which is a process indicating a general fibrotic shift within a certain tissue. It is observed that myofibroblast proliferation decreases significantly on laser treated samples in comparison to non-treated ones. On the other hand endothelial cell proliferation is not affected by the surface topography which is composed of micro- and nanostructures. Such surfaces may be used to modify stent surfaces for prevention or at least reduction of restenosis.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号