基于IGCT的中心点钳位型三电平高压变频器直流环节研究
引用本文:李国栋,毛承雄,陆继明,崔艳艳.基于IGCT的中心点钳位型三电平高压变频器直流环节研究[J].中国电机工程学报,2007,27(1):82-87.
作者姓名:李国栋  毛承雄  陆继明  崔艳艳
作者单位:华中科技大学电气与电子工程学院,湖北省,武汉市,430074
基金项目:教育部跨世纪优秀人才培养计划
摘    要:将IGCT串联技术应用于中性点箝位型三电平高压大功率变频器,研究了变频器直流环节(包括限流电感、箝位电容及限流电阻)对变频器安全运行的影响。通过分析三电平结构的开关暂态过程,建立了变频器暂态开关数学模型,并设计了直流环节部分的限流电抗。在综合考虑三电平的开关过程、直流限流电感的大小及IGCT过压能力的基础上,研究了直流箝位电容对变频器逆变侧持续性直流电压的影响,并推导了直流箝位电容及限流电阻的设计要求。基于PDPWM调制方式,分析了限流电阻对死区时间、最小脉宽及开关频率对开通及关断di/dt的影响,并基于IGCT5SHX14H4502文中设计了6kV、2.5MW二极管箝位型三电平中压变频器直流环节,并通过了6kV高压试验的检验,仿真结果验证了所选参数的有效性。

关 键 词:开关频率  IGCT  中点钳位  三电平  直流环节
文章编号:0258-8013(2007)01-0082-06
收稿时间:2006-05-21
修稿时间:2006年5月21日

Discussion on the DC-link of 6kV NPC Three-level Medium Voltage Drives Based on IGCTs' Series Connection
LI Guo-dong,MAO Cheng-xiong,LU Ji-ming,CUI Yan-yan.Discussion on the DC-link of 6kV NPC Three-level Medium Voltage Drives Based on IGCTs'''' Series Connection[J].Proceedings of the CSEE,2007,27(1):82-87.
Authors:LI Guo-dong  MAO Cheng-xiong  LU Ji-ming  CUI Yan-yan
Abstract:With series connected IGCTs used in neutral point clamped (NPC) three-level medium voltage drives (MVDs), the contribution of the DC-Link (including DC-Link choke, DC-Link resistor and clamped capacitor) to the MVDs safe operation is discussed in this paper. Through the analysis on the turn-on and turn-off transience of NPC three-level MVDs, the corresponding mathematical models are developed, based on which the DC-Link choke value is deduced. With the DC-Link choke, switching transient state and device's over-voltage capability taken into accounts, the relationship among the clamped capacitor, DC-Link resistor and inverter's permanent DC voltage is studied. Accordingly, the design rule of the clamped capacitor and DC-Link resistor is described. For suppressing the high turn-on and turn-off di/dt, the dead time, Min pulse width and the switching frequency are analyzed with the phase disposition pulse width modulation (PDPWM) applied. Furthermore, with the IGCT (5SHX14H4502) used, the DC-Link part of 6kV, 2500kW MVDs is designed. The simulation results confirm its efficiency and the MVDs with the proposed DC-Link passed 6kV tests.
Keywords:IGCT