摘    要:以电解富集——石墨炉原子吸收分光光度法测定水样中痕量Hg~(2+)·100ml水样预富集后最低检出限为0.1ng/ml.对0.6ng/mlHg~(2+)进行10次平行测定的相对标准偏差为4.1%,10多种共存离子不干扰测定.

关 键 词:电解富集 汞 测定 水 分光光度法

Determination of Trace Mercury in Water by Electorlytic Proconcentration and Graphite Furnace Atomic Absorption Spectrophotometry
Xn Shuping Shen Xuchen Cnen Qingping. Determination of Trace Mercury in Water by Electorlytic Proconcentration and Graphite Furnace Atomic Absorption Spectrophotometry[J]. Journal of Shanghai Second Polytechnic University, 1993, 10(2): 48-51
Authors:Xn Shuping Shen Xuchen Cnen Qingping
Affiliation:Xn Shuping Shen Xuchen Cnen Qingping
Abstract:The determination of trace Mercury in water by electorlytic proconcentration and graphite furnace atomic absorption spectrophotometry is described.Ten parallel determinations of 100ml of Solution Containing 0.6ng/ml Hg(11) give relative standard deviation 4.1%, the detection limit 0.1ng/ml, More than 10 coexisted ions do not interfere in determination.
Keywords:electrolytic proconcentration graphite furnace AAS determination of Hg(ll)