首页 | 本学科首页   官方微博 | 高级检索  
     

提高并联电容器回路电能计量精度的研究
引用本文:孔斌,刘宪林,娄北.提高并联电容器回路电能计量精度的研究[J].电测与仪表,2007,44(2):16-18.
作者姓名:孔斌  刘宪林  娄北
作者单位:1. 郑州大学,电气工程学院,郑州,450001
2. 郑州供电公司,郑州,450006
摘    要:用感应式电能表测量并联电容器回路这样低功率因数的负载时,由于功率因数过小,使起动功率很小,导致计量误差过大.为此我们采用电能表的非标准接线来提高计量的准确性.并通过试验,验证了方法的可行性.

关 键 词:低功率因数  计量误差  非标准接线
文章编号:1001-1390(2007)02-0016-03
修稿时间:2006-09-20

Study on increasing measure accuracy of paralleling condenser circuit
KONG Bin,LIU Xian-lin,LOU Bei.Study on increasing measure accuracy of paralleling condenser circuit[J].Electrical Measurement & Instrumentation,2007,44(2):16-18.
Authors:KONG Bin  LIU Xian-lin  LOU Bei
Affiliation:1.Zhengzhou University, Zhengzhou 450001 , China;2.Zhengzhou Power Company, Zhengzhou 450006, China
Abstract:The load such as paralleling condenser have low power factor, because the driving power of induction watt-hour meter is smaller, result in measure error added. So this paper puts forward the method of decreasing measure error via changing standard connect of induction watt-hour meter. Test indicates the method is simple and high accuracy.
Keywords:low power factor  measure error  non-standard connect
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏