首页 | 本学科首页   官方微博 | 高级检索  
     


Comparative evaluation of strain controlled low cycle fatigue behaviour of solution annealed and prior cold worked 316L(N) stainless steel
Authors:V S Srinivasan  R Sandhya  M Valsan  K Bhanu Sankara Rao  S L Mannan  
Affiliation:

Materials Development Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102, Tamil Nadu, India

Abstract:The effect of 20% prior cold work on low cycle fatigue (LCF) behaviour of type 316L(N) stainless steel (SS) was studied at 873 K by conducting total axial strain controlled tests in air with strain amplitudes in the range ±0.25% to ±1.0%. The cyclic deformation behaviour of 20% prior cold worked (PCW) material was compared with the LCF response of solution annealed (SA) alloy tested under similar conditions. The cyclic stress response (CSR) of 316L(N) SS in the PCW condition was characterized by a short period of hardening followed by prolonged softening prior to failure, whereas SA material exhibited a significant hardening regime followed by stress saturation. Interrupted tests on PCW material were carried out at different stages of CSR in order to determine the underlying mechanisms as reflected in substructural changes. The fatigue life in the solution annealed condition was similar to that of the PCW material at higher strain amplitudes of testing (≥±0.5%) while at lower strain amplitudes, the PCW material exhibited longer life.
Keywords:Cyclic hardening  Softening  Dynamic strain ageing  Recovery
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏