首页 | 本学科首页   官方微博 | 高级检索  
     


Effects of supplied gas humidity change on PEFC transient power generation
Authors:So Manabe  Yuki Uemura  Takuto Araki
Affiliation:Graduate School of Engineering, Yokohama National University, Japan
Abstract:Polymer electrolyte fuel cells (PEFCs, PEMFCs) are gaining increasingly more attention as clean and efficient energy‐conversion devices. Vapor and liquid transport has a strong impact on the power generation characteristics and efficiency of PEFCs, and so proper water management is needed for efficiency and durability. However, water transport factors are not well understood, particularly during unsteady operation—often the case in vehicles and distributed stationary power generators. In this study, to understand and generalize the effects of local water transport on PEFC performance, transient mass transport characteristics inside a PEFC were investigated experimentally and numerically. For this purpose, we developed an unsteady two‐dimensional numerical model based on mass‐ and charge‐conservation equations in the channel, gas diffusion layer (GDL), and membrane electrode assembly (MEA). As necessary parameters for model development, we measured the water content of the MEA, the membrane resistivity, the activation overvoltage, overall mass transfer coefficient, and so on. The membrane resistivity greatly increases as the relative humidity decreases. The activation overvoltage is also affected by the relative humidity, and not only by the current density and oxygen activity. Current load and voltage changes are frequently used as PEFC transient inputs, but lead to very complicated and intractable phenomena such as changes in the amount of generated water and electro‐osmosis, state of the electrical double layer, and so on. Hence, stepwise changes in the relative humidity of the supplied gas were adopted in this study. The experimental and numerical transient responses were in good agreement under most operating conditions, and the reliability of our measurement methods for the water transport properties and our numerical model were confirmed. Here we discuss the dominant factor in the transient responses, and conclude that the transport resistance at the PEM–GDL interface is the largest and most dominant factor in a relatively dry state under unsteady operating conditions. © 2011 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley Online Library ( wileyonlinelibrary.com/journal/htj ). DOI 10.1002/htj.20371
Keywords:PEFC  PEMFC  water management  mass transport  transient power generation characteristics
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号