摘    要:实践证明,在特殊情况下,只要做好充分的准备,全系列工业电解槽停电2小时是可行的。并利用此停电机会,对电解质温度及反电动势进行了跟踪检测研究其结果为今后铝电解理论及生产操作提供了重要的参考与借鉴数据。

关 键 词:电解槽  停电  反电动势  原电池

COUNTERMEASURE AND STATE CHARACTERISTIC OF LONG TIME POWER CUT ON WHOLE SERIES INDUSTRIAL CELLS
Wang Xingzhong Cheng Geng Cui Xinfang. COUNTERMEASURE AND STATE CHARACTERISTIC OF LONG TIME POWER CUT ON WHOLE SERIES INDUSTRIAL CELLS[J]. Energy Saving Of Non-Ferrous Metallurgy, 1998, 0(3)
Authors:Wang Xingzhong Cheng Geng Cui Xinfang
Affiliation:China Great Wall Aluminium Company
Abstract:It is proved by practice that under the particular condition as long as make full preparation, power cut for 2 hours on Whole series industrial cells is no problem. During the power cut, inspecting electrolyte temperature and Counter electromotive force, the results which Can be the guide for aluminium electrolytic theory and productive operation in future are given.
Keywords:Cell Power cut Counter electromotive force Primary cell