首页 | 本学科首页   官方微博 | 高级检索  
     

长春市第四净水厂絮凝池的技术改造
引用本文:XIAO Shu-hong,王殿有,HUANG Liao-ru,陈鸿,YIN Chun-yan,吴琼.长春市第四净水厂絮凝池的技术改造[J].中国给水排水,2008,24(16).
作者姓名:XIAO Shu-hong  王殿有  HUANG Liao-ru  陈鸿  YIN Chun-yan  吴琼
作者单位:长春水务集团,吉林,长春,130021
摘    要:为解决净水厂絮凝池效率低、投药量大的问题,对絮凝池的过孔流速进行了调整,合理设置了速度梯度.实施上述改造后,絮凝池的效率得以提高,沉淀池的出水浊度<3.0 NTU,滤后水浊度<1.0 NTU,药耗降低26%.

关 键 词:净水厂  絮凝池  过孔流速  药耗  浊度

Technical Reconstruction of Flocculation Tank in Fourth Water Treatment Plant of Changchun City
XIAO Shu-hong,WANG Dian-you,HUANG Liao-ru,CHEN Hong,YIN Chun-yan,WU Qiong.Technical Reconstruction of Flocculation Tank in Fourth Water Treatment Plant of Changchun City[J].China Water & Wastewater,2008,24(16).
Authors:XIAO Shu-hong  WANG Dian-you  HUANG Liao-ru  CHEN Hong  YIN Chun-yan  WU Qiong
Affiliation:XIAO Shu-hong,WANG Dian-you,HUANG Liao-ru,CHEN Hong,YIN Chun-yan,WU Qiong(Changchun Water Group Co.Ltd.,Changchun 130021,China)
Abstract:In order to solve the problems of low efficiency of flocculation tank in the water treatment plant and high chemicals dosage,the through hole velocity of the flocculation tank was adjusted,and the reasonable velocity gradient was set.After the reconstruction,the efficiency of the flocculation tank is improved.The turbidity of treated water from sedimentation tank is less than 3.0 NTU,the turbidity of filtered water is less than 1.0 NTU,and the chemicals consumption is reduced by 26%.
Keywords:water treatment plant  flocculation tank  through hole velocity  chemicals consumption  turbidity  
本文献已被 CNKI 维普 万方数据 等数据库收录!