Radiation quality of photons in small and large receptors--a microdosimetric analysis |
| |
Authors: | Chen Jing Roos Hartmut Kellerer Albrecht M |
| |
Affiliation: | 1 Radiation Protection Bureau, Health Canada, 775 Brookfield Road, Ottawa K1A 1C1, Canada
2 Radiobiological Institute, University of Munich, Schillerstrasse 42, D-80336, Germany |
| |
Abstract: | The quality of different photon radiations in small and largereceptors is assessed in terms of microdosimetry. Monte Carlosimulations are performed for the electrons released by photons.To represent the case of a small receptor, only electrons releasedby the non-degraded incident photons are tracked. For a largereceptor, all electrons released in the complete degradationprocess are followed. Dose averaged values, yD, of the linealenergy are derived from the simulated tracks for monoenergeticphotons from 10 keV to 2 MeV. In microdosimetry, the dose meanlineal energy is the major parameter of radiation quality. Theresults demonstrate distinct differences in radiation qualitybetween high-energy gamma rays and conventional X rays thatare present not just in small cell samples but also in largereceptors, such as the human body. The values of yD suggestthat, for both small and large receptors, conventional X raysshould be about twice as effective as gamma rays from 60Co. |
| |