首页 | 本学科首页   官方微博 | 高级检索  
     


Measurement of drop size characteristics in annular centrifugal extractors using phase Doppler particle analyzer (PDPA)
Authors:T.V. Tamhane  J.B. Joshi  Kamachi Mudali  R. Natarajan  R.N. Patil
Affiliation:1. Department of Chemical Engineering, Institute of Chemical Technology, Matunga, Mumbai 400019, India;2. Homi Bhabha National Institute, Anushakti Nagar, Mumbai 400094, India;3. Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102, Tamil Nadu, India;4. Techno-Force Pvt. Ltd., Ambad D-34, Nashik 422010, India
Abstract:Drop size distributions have been measured in a 39 mm annular centrifugal extractor using phase Doppler particle analyzer (PDPA). The power consumption and the interfacial tension have been varied in the range of 10–450 kW/m3 and 13–33 mN/m, respectively. The two liquid phases have been selected with different density and viscosity ratios. The results have been analyzed using Rosin–Rammler distribution function. A correlation has been developed for the drop size distribution. The same has been compared with the correlations in the literature.
Keywords:Taylor&ndash  Couette flow   Annular centrifugal extractor   Liquid&ndash  liquid extraction   Power consumption   Drop size distribution   PDPA
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号