首页 | 本学科首页   官方微博 | 高级检索  
     


Improved area—energy targeting for fired heater integrated heat exchanger networks
Authors:James Varghese  Santanu Bandyopadhyay
Affiliation:1. Mechanical Engineering, School of Engineering, Cochin University of Science and Technology, Kochi 682022, Ernakulam, India;2. Department of Energy Science and Engineering, Indian Institute of Technology Bombay, Mumbai 400076, India
Abstract:Effective integration of various subsystems into the overall process, results in an energy efficient and economic plant design. In this paper, issues related to the area-energy targeting for fired heater integrated heat exchanger networks are studied. Performance of a fired heater is affected by the variables such as fuel fired and air-preheat temperature. These variables along with the minimum approach temperature difference for the heat recovery of the background process, affect the performance of the overall system. A methodology is proposed for the area-energy targeting for fired heater integrated processes. In the proposed methodology, the fired heater heat duty split between the radiation and the convection section is determined using the one gas zone furnace model.
Keywords:Fired heater   Fired heater integration   Heat exchanger network   Cost targeting
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏