首页 | 本学科首页   官方微博 | 高级检索  
     


Comprehensive correlation for dispersed flow film boiling heat transfer in mini/macro tubes
Affiliation:10 Dahlia Lane, Redding, CT 06896, USA;Engineering Research Associates, 10 Dahlia Lane, Redding, CT 06896, USA;Engineering Research Associates, 10 Dahlia Lane, Redding, CT 06896, USA;Michigan Technological University, Houghton, MI 49931, USA;Engineering Research Associates, 10 Dahlia Lane, Redding, CT 06896, USA
Abstract:A general correlation for heat transfer during dispersed flow film boiling is presented which is applicable to horizontal and vertical tubes. It is based on the two-step model. It has been verified with data for 10 fluids in horizontal and vertical upflow. The fluids include refrigerants, hydrocarbons, cryogens, CO2 and water. The range of data included diameters from 0.98 to 25.0 mm, reduced pressures from 0.0046 to 0.99, mass flux from 3.7 to 5176 kg m−2 s−1, and qualities from 0.1 to 2.96. The 1481 data points from 38 sources are predicted with mean absolute deviation of 19.4%. Several other correlations are also compared to the same data and found to have much larger deviations.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号