首页 | 本学科首页   官方微博 | 高级检索  
     


Multi-ejector R744 booster refrigerating plant and air conditioning system integration – A theoretical evaluation of energy benefits for supermarket applications
Affiliation:1. Polytechnic Department of Engineering and Architecture, University of Udine, via delle Scienze 206, 33100 Udine, Italy;2. Department of Energy and Process Engineering, NTNU Norwegian University of Science and Technology, Kolbjørn Hejes vei 1D, 7491 Trondheim, Norway
Abstract:The multi-ejector rack is the most promising technology to push the so-called “CO2 equator” further south and improve the global energy efficiency of R744 supermarket refrigeration systems.This paper theoretically compares the energy consumption of a CO2 refrigerating plant equipped with a multi-ejector unit with that of a R404A direct expansion system (DXS), of a conventional CO2 booster configuration and of two CO2 solutions using parallel compression. The energy benefits related to the adoption of low temperature (LT) overfed display cabinets were also assessed. Furthermore, various scenarios involving different sizes of the supermarket, integration and capacity of the air conditioning (AC) system and efficiency of the parallel compressors were investigated. The evaluations were carried out by considering different locations in Southern Europe. The results showed that, as a function of the selected boundary conditions, energy savings ranging from 15.6% to 27.3% could be accomplished with the multi-ejector concept over DXS.
Keywords:
本文献已被 ScienceDirect 等数据库收录!