首页 | 本学科首页   官方微博 | 高级检索  
     


CFD model performance benchmark of fast filling simulations of hydrogen tanks with pre-cooling
Authors:Daniele Melideo  Daniele BaraldiMaria Cristina Galassi  Rafael Ortiz CebollaBeatriz Acosta Iborra  Pietro Moretto
Affiliation:European Commission Joint Research Centre, Institute for Energy and Transport, Westerduinweg 3, P. Box 2, Petten 1755 ZG, Petten, The Netherlands
Abstract:High gas temperatures can be reached inside a hydrogen tank during the filling process because of the large pressure increase (up to 70–80 MPa) and because of the short time (∼3 min) of the process. High temperatures can potentially jeopardize the structural integrity of the storage system and one of the strategies to reduce the temperature increase is to pre-cool the hydrogen before injecting it into the tank. Computational Fluid Dynamics (CFD) tools have the capabilities of capturing the flow field and the temperature rise in the tank. The results of CFD simulations of fast filling with pre-cooling are shown and compared with experimental data to assess the accuracy of the CFD model.
Keywords:Hydrogen   Safety   CFD   Storage   Fast filling
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号