Para-H2 to ortho-H2 conversion in a full-scale automotive cryogenic pressurized hydrogen storage up to 345 bar
Authors:Guillaume Petitpas  Salvador M AcevesManyalibo J Matthews  James R Smith
Affiliation:Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550, USA
Abstract:Hydrogen vehicles offer the potential to improve energy independence and lower emissions but suffer from reduced driving range. Cryogenic pressure vessel storage (also known as cryo-compressed storage) offers the advantage of higher densities than room temperature compressed although it has the disadvantage of cryogenic operating temperatures which results in boil-off when the temperature of the gas increases. In order to understand and optimize the time prior to boil-off, we have examined heat absorption from the transition between the two quantum states of the hydrogen molecule (para–ortho) in a full-scale (151 L internal volume) automotive cryogenic pressure vessel at pressures and temperatures up to 345 bar and 300 K, and densities between 14 and 67 g/L (2.1–10.1 kg H2). The relative concentration of the two species was measured using rotational Raman scattering and verified by calorimetry. In fifteen experiments spanning a full year, we repeatedly filled the vessel with saturated LH2 at near ambient pressure (2–3 bar), very low temperatures (20.3–25 K), varying densities, and very high para-H2 fraction (99.7%). We subsequently monitored vessel pressure and temperature while performing periodic ortho-H2 concentration measurements with rotational Raman scattering as the vessel warmed up and pressurized due to environmental heat entry. Experiments show that para–ortho H2 conversion typically becomes active after 10–15 days of dormancy (“initiation” stage), when H2 temperature reaches 70–80 K. Para–ortho H2 conversion then approaches completion (equilibrium) in 25–30 days, when the vessel reaches 100–120 K at ∼50 g/L density. Warmer temperatures are necessary for conversion at lower densities, but the number of days remains unchanged. Vessel dormancy (time that the vessel can absorb heat from the environment before having to vent fuel to avoid exceeding vessel rating) increased between 3 and 7 days depending on hydrogen density, therefore indicating a potentially large benefit for reduced fuel venting in cryogenic pressurized hydrogen storage.
Keywords:Liquid hydrogen  Cryogenic pressure vessel  On-board H2 storage  Para&ndash  ortho conversion  Dormancy  Raman spectroscopy
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号