首页 | 本学科首页   官方微博 | 高级检索  
     


Research on the inherent error of ultrasonic flowmeter in non-ideal hydrogen flow fields
Authors:Qiang Chen  Jiangtao Wu
Affiliation:MOE Key Laboratory of Thermo-Fluid Science and Engineering, Xi''an Jiaotong University, Shaanxi 710049, People''s Republic of China
Abstract:For the widespread transmission, custody and utilization for hydrogen energy, accurate flow rate measurement is the precondition. The ultrasonic flowmeter has a prospect of wide application for the hydrogen flow measurement. To improve the measurement accuracy, this article researched the inherent error of the ultrasonic flowmeter in the non-ideal hydrogen gas flow. Computational fluid dynamics (CFD) had been used to simulate hydrogen flows downstream of the single right bend and an orifice plate at different Reynolds numbers. Based on the simulation results, this work investigated the inherent error of the ultrasonic flowmeter with different integrations and acoustic paths. The results show the errors become larger when the flowmeter position is closer to the disturbance sources. The increase in the number of acoustic paths can effectively reduce the error caused by the non-ideal flow. In the flow field downstream of the bend, the flowmeters adopting Tailored and Owics integration perform better than those with other integrations. Tchebychev and Owics integration cause less error in the front 4D (four times diameter) pipe downstream of the orifice plate, while Tailored and Owics cause less error in the rear 11D area.
Keywords:Hydrogen  Non-ideal flow  Inherent error  Integration  Ultrasonic flowmeter
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏