捷制直流锅炉启动分析
引用本文:支国军,谭卫民.捷制直流锅炉启动分析[J].电力学报,1999,14(1):28-30.
作者姓名:支国军  谭卫民
作者单位:[1]太原电力高等专科学校 [2]神头第一发电厂
摘    要:神头一电厂四台捷制直流锅炉在启动过程中,第一套制粉系统投入时,屏式过热器壁温摆动很大。针对这一问题,本文将着重分析原因并提出正确控制启动过程与解决问题的措施。

关 键 词:直流锅炉  启动  控制

A start-up Analysis of a Czechoslovakia-made once-through Boiler
Zhi Guojun, Tan Weimin.A start-up Analysis of a Czechoslovakia-made once-through Boiler[J].Journal of Electric Power,1999,14(1):28-30.
Authors:Zhi Guojun  Tan Weimin
Affiliation:Zhi Guojun; Tan Weimin(Tai Yuan Higher Electrcal Power college) (Shen Tou No. 1 Power Plant )
Abstract:When the first coal puerizing csystem at the start - up of 4 Czcchoslovakia - made 650t/h once-through boilers was put into opreation,the wall temperature of plulen superheater varied greatly. After a careful anhlysis for its reasons,a correct start - up procedure and the measures to solve problem are given.
Keywords:once-through boiler  start-up  control  