首页 | 本学科首页   官方微博 | 高级检索  
     

真空冷却联合超声杀菌对卤牛肉品质的影响
引用本文:高飞,蔡华珍,陈彦豪,杜庆飞,张信东,陈先林,武运.真空冷却联合超声杀菌对卤牛肉品质的影响[J].食品工业科技,2022,43(13):63-70.
作者姓名:高飞  蔡华珍  陈彦豪  杜庆飞  张信东  陈先林  武运
作者单位:1.滁州学院生物与食品工程学院,安徽滁州 2390002.新疆农业大学食品科学与药学学院,新疆乌鲁木齐 8300523.天长市厚强家味食品有限公司,安徽天长 2393994.安徽徽食食品有限公司,安徽滁州 239000
基金项目:天长市智能装备及仪表研究院专项发展基金(tzy202119);安徽省科技厅科技重大专项(18030701165);企业横向项目(20201100288)。
摘    要:为避免高温杀菌给卤牛肉带来的不利影响,探索绿色低温处理在保障卤牛肉安全和良好品质方面的可行性,以菌落总数、TVB-N、TBARS、感官与水分分布等为指标,采用单因素实验、对比实验等方法,开展真空冷却-超声杀菌对卤牛肉品质影响方面的研究。结果表明,基于真空冷却的超声波处理功率、温度和时间对杀菌效果影响明显,超声波功率为2500 W、处理温度70 ℃、杀菌时间20 min时杀菌效果最好,显著降低了菌落总数、TVB-N和TBARS值(P<0.05)。真空冷却联合超声杀菌的卤牛肉结构完整、紧实,横向弛豫时间T2明显左移,弛豫时间缩短,水与肉成分结合度高,分布均匀。真空冷却联合超声处理对卤牛肉具有明显的杀菌作用,并能延缓卤牛肉中脂肪的氧化,保质效果好。该研究可为酱卤肉制品的绿色低温杀菌提供借鉴。

关 键 词:真空冷却    超声处理    卤牛肉    低温杀菌    水分分布
收稿时间:2021-10-12

Effect of Vacuum Cooling Combined with Ultrasonic Sterilization on Quality of Marinated Beef
GAO Fei,CAI Huazhen,CHEN Yanhao,DU Qingfei,ZHANG Xindong,CHEN Xianlin,WU Yun.Effect of Vacuum Cooling Combined with Ultrasonic Sterilization on Quality of Marinated Beef[J].Science and Technology of Food Industry,2022,43(13):63-70.
Authors:GAO Fei  CAI Huazhen  CHEN Yanhao  DU Qingfei  ZHANG Xindong  CHEN Xianlin  WU Yun
Affiliation:1.College of Biology and Food Engineering, Chuzhou University, Chuzhou 239000, China2.College of Food Science and Pharmacy, Xinjiang Agricultural University, Urumqi 830052, China3.Tianchang Houqiang Jiawei Food Co., Ltd., Tianchang 239399, China4.Anhui Huishi Food Co., Ltd., Chuzhou 239000, China
Abstract:In order to avoid the adverse effects of high-temperature sterilization on stewed beef and explore the feasibility of green low-temperature treatment in ensuring the safety and good quality of stewed beef, taking the total number of colonies, TVB-N, TBARS, sensory and moisture distribution as indicators, the effects of vacuum cooling combined with ultrasonic sterilization on the quality of stewed beef were studied by single factor experiment and comparative experiment. The results showed that the ultrasonic treatment power, temperature and time based on vacuum cooling had an obvious impact on the sterilization effect. The sterilization effect was the best when the ultrasonic power was 2500 W, the treatment temperature was 70 ℃ and the sterilization time was 20 min, which significantly reduced the total number of colonies, TVB-N and TBARS (P<0.05). The stewed beef treated by vacuum cooling combined with ultrasonic sterilization had complete and compact structure, obvious left shift of transverse relaxation time T2, shortening of relaxation time, high combination of water and meat components and uniform distribution. Vacuum cooling combined with ultrasonic treatment had obvious bactericidal effect on stewed beef, could delay the oxidation of fat in stewed beef, and had good quality. This study can provide a reference for the green low-temperature sterilization of sauce and marinated meat products.
Keywords:
点击此处可从《食品工业科技》浏览原始摘要信息
点击此处可从《食品工业科技》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号