首页 | 本学科首页   官方微博 | 高级检索  
     

ANALYSIS OF INTERNALLY GENERATED NOISE OF BIOELECTRIC AMPLIFIERS
引用本文:MashhourMustafaBaniAmer. ANALYSIS OF INTERNALLY GENERATED NOISE OF BIOELECTRIC AMPLIFIERS[J]. 电子科学学刊(英文版), 2003, 20(1): 20-28. DOI: 10.1007/s11767-003-0082-y
作者姓名:MashhourMustafaBaniAmer
作者单位:Dept,ofBiomedicalEng,FacultyofEng,JordanUniv.ofSci.andTech,P.O.Box3030,Irbid22110,Jordan
摘    要:This papenr deals with internally generated noise of bioelectric amplifiers that are usually used for processing of bioelectric events.The main purpose of this paper is to present a procedure for analysis of the effects of internal noise generated by the active circuits and to evaluate the output noise of the author‘s new designed bioelectric amplifier that caused by internal effects to the amplifier circuit itself in order to compare it with the noise generated by conventional amplifiers.The obtained analysis results of internally generated noise showed that the total output noise of bioelectric active circuits does not increase when some of their resitors have a larger value.This behavior is caused by the different transfer functions for the signal and the respective noise sources associated with these resistors.Moreover,the new designed bioelectric amplifier haws an output noise less than that for conventional amplifiers.The obtained analysis results were also experimentally verified and the final conclusions were drawn.

关 键 词:噪声分析 总噪音输出 生物电放大器 内部噪声
收稿时间:2001-08-13

Analysis of internally generated noise of bioelectric amplifiers
Mashhour Mustafa Bani Amer. Analysis of internally generated noise of bioelectric amplifiers[J]. Journal of Electronics, 2003, 20(1): 20-28. DOI: 10.1007/s11767-003-0082-y
Authors:Mashhour Mustafa Bani Amer
Affiliation:Dept. of Biomedical Eng., Faculty of Eng., Jordan Univ. of Sci. and Tech., P.O.Box 3030, Irbid 22110, Jordan
Abstract:This paper deals with internally generated noise of bioelectric amplifiers that are usually used for processing of bioelectric events. The main purpose of this paper is to present a procedure for analysis of the effects of internal noise generated by the active circuits and to evaluate the output noise of the author's new designed bioelectric amplifier that caused by internal effects to the amplifier circuit itself in order to compare it with the noise generated by conventional amplifiers. The obtained analysis results of internally generated noise showed that the total output noise of bioelectric active circuits does not increase when some of their resistors have a larger value. This behavior is caused by the different transfer functions for the signal and the respective noise sources associated with these resistors. Moreover, the new designed bioelectric amplifier has an output noise less than that for conventional amplifiers. The obtained analysis results were also experimentally verified and the final conclusions were drawn.
Keywords:Noise analysis  Bioelectric amplifier  Total output noise
本文献已被 CNKI 维普 万方数据 SpringerLink 等数据库收录!
点击此处可从《电子科学学刊(英文版)》浏览原始摘要信息
点击此处可从《电子科学学刊(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号