首页 | 本学科首页   官方微博 | 高级检索  
     

卷烟主流烟气中吡啶、喹啉和苯乙烯的GC/MS测定
引用本文:吴银菊,禹文峰,瞿白露,许雄飞,庄琼华.卷烟主流烟气中吡啶、喹啉和苯乙烯的GC/MS测定[J].精细化工中间体,2011,41(4):70-72.
作者姓名:吴银菊  禹文峰  瞿白露  许雄飞  庄琼华
作者单位:长沙市环境监测中心站,湖南长沙,410001
摘    要:采用剑桥滤片捕集卷烟主流烟气粒相物中的吡啶、喹啉和苯乙烯,用甲醇溶液萃取,萃取液经0.45μm滤膜后,气相色谱/质谱联用(GC/MS)测定分析卷烟主流烟气粒相物中的吡啶、喹啉和苯乙烯3种半挥发性物质含量,3种物质的线性范围分别为0.6~12.0、0.2~6.0、0.1~0.8μg/mL,检出限分别为0.54、0.03、0.03 ng/cig,相关系数(r2)达到0.995以上。

关 键 词:GC/MS  主流烟气  吡啶  喹啉  苯乙烯

Determination of Pyridine,Quinoline and Styrene in Mainstream Cigarette Smoke by Gas Chromatography Coupled with Mass Spectrometry
WU Yin-ju,YU Wen-feng,QU Bai-lu,XU Xiong-fei,ZHUANG Qiong-hua.Determination of Pyridine,Quinoline and Styrene in Mainstream Cigarette Smoke by Gas Chromatography Coupled with Mass Spectrometry[J].Fine Chemical Intermediates,2011,41(4):70-72.
Authors:WU Yin-ju  YU Wen-feng  QU Bai-lu  XU Xiong-fei  ZHUANG Qiong-hua
Affiliation:WU Yin-ju,YU Wen-feng,QU Bai-lu,XU Xiong-fei,ZHUANG Qiong-hua(Changsha Environmental Monitoring Central Station,Changsha 410001,China)
Abstract:Pyridine,quinoline and styrene in mainstream cigarette smoke were collected by Cambridge pad and extracted with CH3OH.The extract was filtered with a 0.45 μm membrane and then analyzed with GC/MS to quantify the three substances.The linear range of the method was 0.6~12.0 μg/mL,0.2~6.0 μg/mL and 0.1~0.8 μg/mL respectively.The detection limit was 0.54 ng/cig,0.03 ng/cig and 0.03 ng/cig respectively.The correlation coefficient was over 0.995.
Keywords:gas chromatography/mass spectrometry  mainstream smoke  pyridine  quinoline  styrene  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号