高湿度高山风电场的防雷接地设计
引用本文:杜华. 高湿度高山风电场的防雷接地设计[J]. 红水河, 2014, 0(3): 16-18
作者姓名:杜华
作者单位:广西电力工业勘察设计研究院,广西南宁530023
摘    要:针对亚热带季风湿润气候区高山风电场,冬季气温低、太阳辐射小,空气湿度大、霜雪期长、冻雨灾害严重、雷暴日多等特点,对风力发电机组、箱式变压器的防雷接地设计谈谈工作体会,经验可供同类风电场设计人员参考。

关 键 词:高山风电场  防雷接地

Lightning Protection and Grounding Design for High Humidity Mountain Wind Farm
DU Hua. Lightning Protection and Grounding Design for High Humidity Mountain Wind Farm[J]. Hongshui River, 2014, 0(3): 16-18
Authors:DU Hua
Affiliation:DU Hua (Guangxi Electric Power Industry Investigation Design and Research Institute, Nanning, Guangxi, 530023)
Abstract:The paper makes a discussion on the lightning protection and grounding design for wind generating sets and box-type transformer based on the characteristics of high mountain wind farm in subtropical humid monsoon cli- mate area, such as low temperatures in winter, small solar radiation, great air humidity, long frost period, severe freez- ing rain disaster and many thunderstorm days, which can be well referenced by similar wind farm projects.
Keywords:high mountain wind farm  lightning protection and grounding