首页 | 本学科首页   官方微博 | 高级检索  
     


High-frequency transducers and correlation method to enhance ultrasonic gas flow metering
Affiliation:1. Laboratoire de Mécanique Physique, UMR CNRS 5469–Université Bordeaux 1, 351 Cours de la Libération, F-33405 Talence Cedex, France;2. Direction de la Recherche–Gaz de France, 1–3 Chemin de Villeneuve, F-94140 Alfortville, France;1. Graduate School of Science and Engineering, Tokyo Institute of Technology, Tokyo, Japan;2. Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, Tokyo, Japan;1. Tianjin Key Laboratory of Process Measurement and Control, School of Electrical Engineering & Automation, Tianjin University, Tianjin 300072, China;2. Aeronautical Automation College, Civil Aviation University of China, Tianjin 300300, China;1. Division of Physical Metrology, Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea;2. Technology Support Center, Korea Gas Corporation, 950 Incheonsinhang-daero, Yeonsu-gu, Incheon 21993, Republic of Korea
Abstract:Research activities carried out in past years have shown that in gas networks some constraints exist on the frequency at which ultrasonic transducers can be operated. The study of the transmission and attenuation of the signal and noise mechanisms gives us a defined suitable frequency range (K.R. Wild, A European collaboration to evaluate the application of multi-path ultrasonic gas flow meters, paper presented at 4th International Symposium on Fluid Flow Measurement, Denver, CO, 1999). A working frequency of 500 kHz proves to be the most suitable to avoid noise effects. This frequency is above the noise level detected in gas pipelines. Moreover, the signal loss due to attenuation of ultrasound in gas is still negligible.In parallel, the use of this frequency allows the application of efficient numerical techniques such as the cross-correlation method for signal processing. An initial process based on this method has been developed for gas flowmeters. It provides low uncertainty for the parameters involved in the flow measurement process.A single-path flowmeter equipped with this system has been tested on the Gaz de France test facilities. Its accuracy is better than 1.5% from 250 to 1000 m3/h without initial adjustment. An auto-calibration process also forms part of the system, using a systematic comparison between ultrasonic measurement of sound velocity and a theoretical approach. The signal-to-noise ratio remains large enough to perform the measurements correctly, even with a control valve installed close to the flowmeter.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号