首页 | 本学科首页   官方微博 | 高级检索  
     

低压蒸汽过热器腐蚀分析及预防措施
引用本文:李立东. 低压蒸汽过热器腐蚀分析及预防措施[J]. 化肥设计, 2020, 58(1): 24-26. DOI: 10.3969/j.issn.1004-8901.2020.01.007
作者姓名:李立东
作者单位:中国五环工程有限公司,湖北 武汉 430223
摘    要:某项目投产运行大约18个月后,低压蒸汽过热器先后几次发生换热管开裂泄漏现象。将换热器解体后,通过对换热管取样进行化学成分分析、能谱分析、扫描电镜分析、金相组织分析,发现换热管发生泄漏的原因是由氯化物腐蚀引起的,提出了相应的预防措施,为低压蒸汽过热器长期运行提供借鉴。

关 键 词:低压蒸汽过热器  应力腐蚀  预防措施

Corrosion Analysis and Preventive Measures of Low-Pressure Steam Super-heater
LI Li-dong. Corrosion Analysis and Preventive Measures of Low-Pressure Steam Super-heater[J]. Chemical Fertilizer Design, 2020, 58(1): 24-26. DOI: 10.3969/j.issn.1004-8901.2020.01.007
Authors:LI Li-dong
Affiliation:(Wuhuan Engineering Co.,Ltd.,Wuhan Hubei 430223,China)
Abstract:About 18 months after a project was put into operation,cracking and leakage occurred several times to the heat exchange tubes of a low-pressure super-heater.After the heat exchanger disassembly,chemical composition analysis,energy spectrum analysis,scanning electron microscope analysis and metallographic structure analysis were conducted on the sample from the heat exchange tube.It was found that the leakage of the heat exchange tube is caused by chloride corrosion.Corresponding preventive measures are put forward to provide reference for the long-term operation of low-pressure steam super-heater.
Keywords:low-pressure steam super-heater  stress corrosion  preventive measures