NHD脱碳溶液氨冷器硫堵的清洗总结
引用本文:荆云峰. NHD脱碳溶液氨冷器硫堵的清洗总结[J]. 煤化工, 2005, 33(1): 55-56
作者姓名:荆云峰
作者单位:山西丰喜肥业集团临猗分公司,临猗,044100
摘    要:造成NHD 脱碳氨冷凝器冷却效果降低的原因是油污和单质硫黏附在列管内壁及列管上。通过用80℃~90℃的蒸汽冷凝液冲洗列管内壁并在氨冷器溶液排气口通入0.4MPa蒸汽来溶硫将其吹出,使氨冷器换热效果大大增强。

关 键 词:NHD  脱碳  油污  单质硫
文章编号:1005-9598(2005)-01-0055-02
修稿时间:2004-10-25

Cleaning of Sulfur Blockage in Ammonia Cooler for Decarbonization by NHD
Jing Yunfeng. Cleaning of Sulfur Blockage in Ammonia Cooler for Decarbonization by NHD[J]. Coal Chemical Industry, 2005, 33(1): 55-56
Authors:Jing Yunfeng
Abstract:The cause of sulfur blockage in ammonia cooler for decarbonization by NHD is that smear and elemental sulfur are adhered to the internal walls of the tube bundles. By flushing the internal walls of the tube bundles by 80℃~90℃ steam condensate and blowing in the dissolved sulfur through the exhaust nozzle of the ammonia cooler with 0.4MPa steam, the heat exchange efficiency was improved greatly.
Keywords:decarbonization by NHD   smear   elemental sulfur  