首页 | 本学科首页   官方微博 | 高级检索  
     

双参数立式储罐隔震设计
引用本文:孙建刚,齐晗兵,王莉莉.双参数立式储罐隔震设计[J].哈尔滨工业大学学报,2008,40(6):970-973.
作者姓名:孙建刚  齐晗兵  王莉莉
作者单位:1. 大连民族学院,土木建筑工程学院,辽宁,大连,116600
2. 大庆石油学院土木建筑工程学院,黑龙江,大庆,163318
3. 大庆石油学院土木建筑工程学院,黑龙江,大庆,163318;哈尔滨工程大学,建筑工程学院,哈尔滨,150001
摘    要:由于贮存液体的立式储罐在受到外激力作用时,晃动和液固耦联振动可以分别考虑,且刚性质量脉冲所产生的动效应可以忽略,所以抗震设计时,晃动(对流质量)控制储罐的波高设计,耦联振动控制储罐的基底弯矩和轴向应力设计.基于这一思想,对大型立式钢制储罐的隔震设计问题,提出了考虑晃动和液固耦联振动双约束下的储罐隔震设计方法.数值分析表明,理想的隔震园频率为2~3 rad/s,在阻尼比为0.1时,对于不同容积储罐在不同场地的情况下,其隔震减震效果均达40%以上.增大隔震阻尼比,可提高减震效果,但考虑工程应用实际,隔震阻尼比宜取0.1~0.3.

关 键 词:立式储罐  隔震设计  双参数约束

Seismic isolation design of standing tanks on the basis of double parameters
SUN Jian-gang,QI Han-bing,WANG Li-li.Seismic isolation design of standing tanks on the basis of double parameters[J].Journal of Harbin Institute of Technology,2008,40(6):970-973.
Authors:SUN Jian-gang  QI Han-bing  WANG Li-li
Affiliation:2,3 (1.College of Civil and Architecture Engineering,Dalian Nationalities University,Dalian 116600,China,2.College of Civil and Architecture Engineering,Daqing Petroleum University,Daqing,163318,China;3.College of Construction Engineering,Harbin Engineering Institute,Harbin,150001,China)
Abstract:Since to the rocking vibration and the liquid-solid coupling vibration can be considered respectively and the seismic effect of the rigidity impulse can be ignored when the liquid-filled tank is subjected to excitation,the seismic design of the wave height is controlled by the rocking vibration(convection mass),and the seismic design of the base moment and the axial stress is controlled by the coupling vibration.Aiming at the seismic isolation design of large steel standing tanks,a double-restriction seismic isolation design considering both rocking and liquid-solid coupling vibration is presented.Numerical analysis shows that the ideal natural frequency of isolation is 2-3 rad/s;when the damping ratio is 0.1,for different volume storage tanks at different circumstances,the seismic isolation effect can reach up to 40%.Increasing of isolation damping ratio will increase the damping effect.For the practical application of engineering,the isolation damping ratio is better in the range of 0.1-0.3.
Keywords:standing tank  seismic isolation design  double parameters restriction
本文献已被 CNKI 维普 万方数据 等数据库收录!