首页 | 本学科首页   官方微博 | 高级检索  
     

吸收塔液位计引出管腐蚀失效分析
引用本文:尹大志,呼立红.吸收塔液位计引出管腐蚀失效分析[J].辽宁化工,2010,39(5):551-553.
作者姓名:尹大志  呼立红
作者单位:1. 沈阳石蜡化工有限公司,辽宁,沈阳,110141
2. 国家金属腐蚀控制工程技术研究中心,辽宁,沈阳,110016
摘    要:催化装置的吸收稳定系统的液位计引出管在运行中出现开裂现象,通过电镜观察、能谱分析、X射线衍射分析,以及金相检测等手段,对开裂的原因及机理进行了分析,并提出了关于材料本身和工艺的改进措施。

关 键 词:催化裂化  吸收系统  腐蚀失效

Corrosion Failure Analysis of Level Gauge Nozzle for Adsorption Tower
YIN Da-zhi,HU Li-hong.Corrosion Failure Analysis of Level Gauge Nozzle for Adsorption Tower[J].Liaoning Chemical Industry,2010,39(5):551-553.
Authors:YIN Da-zhi  HU Li-hong
Affiliation:1.Shenyang Paraffin Chemical CO,LTD,Shenyang 110141,China;2.National Engineering Research Center for Corrosion Control of Metals,Shenyang 110016,China )
Abstract:The level gauge nozzle of adsorption tower often appeared crack during operation,crack reason and mechanism were analyzed by SEM,EDX,XRD and metallographical test,the improvement measures were put forward finally.
Keywords:Catalytic cracking  Adsorption system  Corrosion failure analysis
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号