Fabrication and mechanical testing of glass chips for high-pressure synthetic or analytical chemistry
Authors:R E Oosterbroek  D C Hermes  M Kakuta  F Benito-Lopez  J G E Gardeniers  W Verboom  D N Reinhoudt  A van den Berg
Affiliation:(1) BIOS-Lab-on-a-Chip group, MESA+ Research Institute, University of Twente, 7500, AE, Enschede, The Netherlands;(2) Supra Molecular Chemistry and Technology group, MESA+ Research Institute, University of Twente, 7500, AE, Enschede, The Netherlands
Abstract:The pressure strength of microfluidics glass chips for high-pressure chemistry has been examined. Internal pressures up to 320 bar have been measured, although variations are substantial. Long annealing steps at high temperatures did not show any improvement, but smoothening the powder blasted channel walls by isotropic etching did. Although macro cracks are observed at the bond interface it is believed that the formation of micro cracks in the channel wall and stress concentrations due to sharp corners in the channel cross-section geometry strongly limits the maximum applicable pressures.
Keywords:Direct wafer bonding  High pressure  Microreactors  Lab-on-a-chip