BCL507压缩机轴位移故障分析与处理措施
引用本文:王邦旭.BCL507压缩机轴位移故障分析与处理措施[J].化工设备与管道,2014,51(6):50-54.
作者姓名:王邦旭
作者单位:中海石油建滔化工有限公司,海南东方,572600
摘    要:根据甲醇装置合成气压缩机低压缸转子轴位移异常现象,列举出引起压缩机轴位移异常的原因:介质流量变化、排气和进气压差变化、轴位移监测仪表故障、联轴器预拉伸量不合适、止推轴承故障、平衡管堵塞和平衡鼓密封过度磨损或者涂层脱落.结合设备安装和运行的历史记录,通过分析排除方法,推断出此次合成气压缩机低压缸转子轴位移异常的原因是平衡鼓密封涂层脱落.经过拆检证实该推断正确,为准确及时处理故障提供参考.

关 键 词:压缩机  轴位移故障  分析  处理措施

Failure Analysis of Displacement of Shaft in BCL507 Compressor and Treatment Measures
WANG Bangxu.Failure Analysis of Displacement of Shaft in BCL507 Compressor and Treatment Measures[J].Process Equipment & Piping,2014,51(6):50-54.
Authors:WANG Bangxu
Affiliation:WANG Bangxu(CNOOC Kingboard Chemical Limited, Dongfang Hainan 572600, China)
Abstract:With respect to the phenomena that abnormal displacement occurred in the rotary shaft in synthesis gas compressor used alcohol plant,the causes were analyzed and listed as:the change of medium flow,the change of differential pressure at inlet and outlet,the faults occurred in shaft displacement monitoring instrument,inappropriate pre-stretch for coupling,faults of thrust bearing,block in balance pipe,and excessive wear of seal or peeling of coating in balance drum.Combined with the installation and operation history of the equipment and using analytic removing method,it was deduced that abnormal displacement occurred in the rotary shaft is due to the peeling of the seal coating in balance drum,which has been proved to be correct from the result of dismounting the machine.What presented in this article may be referenced in treating faults occurred later.
Keywords:compressor  fault of shaft displacement  analysis  treatment measure