气化炉顶部烧损的现场修理
引用本文:韩冰,叶冬梅. 气化炉顶部烧损的现场修理[J]. 化工设备与管道, 2014, 51(6): 31-35
作者姓名:韩冰  叶冬梅
作者单位:中石化集团南化公司化工机械厂,南京,210048
摘    要:描述了煤气化炉在运行过程中,因内衬耐火层损坏导致炉顶烧损,通过对顶部封头材料进行无损检测、金相检查、硬度测试等确定了具体烧损范围,由此制定了通过加大顶部法兰底部直径进行更换的修理方案并实施,使设备恢复了正常运行.

关 键 词:气化炉  烧损  检测  修理

Onsite Repair of Destruction Occurred in Top of Gasifier
HAN Bing,YE Dongmei. Onsite Repair of Destruction Occurred in Top of Gasifier[J]. Process Equipment & Piping, 2014, 51(6): 31-35
Authors:HAN Bing  YE Dongmei
Affiliation:(SINOPEC Nanjing Chemical Co., Chemical Machinery Plant, Nanjing 210048, China)
Abstract:In this article,the destruction,which was resulted from the damage of inner insulator,occurred in coal gasifier was described.Based on the results of NDT,metallurgical examination and hardness test,the scope of destruction was determined.Then the repair plan,in which top flange is changed with larger diameter scope,was made and implemented,and the gasifier was recovered for normal operation.
Keywords:gasifier  destruction  examination  repair