首页 | 本学科首页   官方微博 | 高级检索  
     

主风机组轴瓦温度异常分析及对策
引用本文:厉勇,郑娥. 主风机组轴瓦温度异常分析及对策[J]. 化工设备与管道, 2014, 51(6): 55-57
作者姓名:厉勇  郑娥
作者单位:中石化洛阳分公司,洛阳三诺化工,河南洛阳471012
摘    要:催化主风机组日常运行中轴瓦温度持续偏高,通过对影响主风机组轴瓦温度的各种因素进行逐项分析,查找出问题原因,制定日常操作运行方案,最终在检修中确认故障原因为轴瓦间隙不合适所致,并予以消除,为以后类似故障处理提供了经验.

关 键 词:主风机  轴瓦  温度

Analysis of Abnormal Temperature in Bearing Bush Used in Main Blower Set
LI Yong,ZHENG E. Analysis of Abnormal Temperature in Bearing Bush Used in Main Blower Set[J]. Process Equipment & Piping, 2014, 51(6): 55-57
Authors:LI Yong  ZHENG E
Affiliation:(Sinopec Luoyang Company, Luoyang San Nuo Chemical Co., Ltd, Luoyang 471012, China)
Abstract:In normal operation of blower machine set used in catalyzing process,the temperature of bearing bush is continuously high.Every factor which may cause this phenomenon was analyzed,it was found finally from repair process that the fault was caused from improper gap in bearing bush.And then this gap was adjusted,which provides experience for treating the similar faults later.
Keywords:main blower  bearing bush  temperature