原油罐区加热系统冬季运行节能分析
引用本文:陈庭辉.原油罐区加热系统冬季运行节能分析[J].石化技术,2009,16(1):47-49.
作者姓名:陈庭辉
作者单位:中国石油化工股份有限公司北京燕山分公司炼油厂,北京,102500
摘    要:针对冬季原油罐区能耗较高的问题,对原油储罐的加热系统进行了热力计算。结果表明,储罐加热盘管间歇运行既可以保证原油的安全存储,又节约了能源。冬季2台热媒炉满负荷运行需消耗天然气3.56×10^6Nm^3,加热盘管间歇运行后,2台热媒炉仅消耗天然气2.27×10^6Nm^3,节省人民币249万元,经济效益显著。

关 键 词:原油  能耗  加热系统

Energy-saving Analysis of Heating System for Crude Oil Tank Farm in Winter
Chen Tinghui.Energy-saving Analysis of Heating System for Crude Oil Tank Farm in Winter[J].Petrochemical Industry Technology,2009,16(1):47-49.
Authors:Chen Tinghui
Affiliation:Chen Tinghui (Refinery of Beijing Yanshan Petrochemical Co., Ltd., SINOPEC, Beijing, 102500)
Abstract:Based on the problem of higher energy consumption in crude oil tank farm in winter, the calorie value for the farm was calculated. The results showed that both the safety of crude oil and energy-saving can be ensured in intermittent operation of the heating coil in tanks. The natural gas consumption for continuous heating was 3.56×10^6 Nm^3, the consumption for the coil intermittent heated has been 2.27×10^6 Nm^3, ¥2.49 million saved.
Keywords:crude oil  energy consumption  heating system