首页 | 本学科首页   官方微博 | 高级检索  
     

电子鼻检测不同贮藏温度下猪肉新鲜度变化
引用本文:顾赛麒,王锡昌,刘源,赵勇,张晶晶,谢晶,郑景洲.电子鼻检测不同贮藏温度下猪肉新鲜度变化[J].食品科学,2010,31(6):172-176.
作者姓名:顾赛麒  王锡昌  刘源  赵勇  张晶晶  谢晶  郑景洲
作者单位:1.上海海洋大学食品学院 2.法国阿尔法莫斯公司上海代表处
基金项目:国家“863”计划项目(2008AA100804); 上海市科委重大科技攻关项目(07dz19508); 上海市科委启明星计划项目(07QA14047)
摘    要:采用电子鼻研究冷却猪肉在不同贮藏温度(- 18、0、4、10、20℃)条件下新鲜度变化规律。选用优化后的进样体积(1500μL)进样,对实验数据进行主成分分析(PCA)、货架期模拟及拟合感官评分的偏最小二乘回归分析(PLS)。结果表明:5 种温度条件下贮藏不同时间肉样挥发性气味差异显著,贮藏温度越高肉样新鲜度发生显著下降时刻越早,预测时间分别为336、180、72、48、18h。对4、20℃条件下电子鼻检测数据与感官评分拟合后进行PLS 分析,相关系数分别高达0.9982和0.9998,表明电子鼻能代替感官评定。逐一选取每一根传感器进行PLS 拟合后发现,TA/2、T40/1、T40/2、P30/2、P40/1、P10/2、P10/1 是对不同新鲜度肉样挥发性气味具有良好特异性响应的传感器。

关 键 词:电子鼻  冷却猪肉  挥发性气味  新鲜度  货架期  
收稿时间:2009-04-27

Electronic Nose for Measurement of Freshness Change of Chilled Pork during Storage at Different Temperatures
GU Sai-qi,WANG Xi-chang,LIU Yuan,ZHAO Yong,ZHANG Jing-jing,XIE Jing,ZHENG Jing-zhou.Electronic Nose for Measurement of Freshness Change of Chilled Pork during Storage at Different Temperatures[J].Food Science,2010,31(6):172-176.
Authors:GU Sai-qi  WANG Xi-chang  LIU Yuan    ZHAO Yong  ZHANG Jing-jing  XIE Jing  ZHENG Jing-zhou
Affiliation:(1. College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China; 2. Alpha M. O. S. Shanghai Representative Office, Shanghai 200336, China)
Abstract:Electronic nose was used to measure the freshness change of chilled pork during storage at -18, 0, 4, 10 or 20 ℃. Injection volume of minced samples was optimized to be 1500 μL. Principal component analysis (PCA) of volatile odor of chilled pork was conducted. Electronic nose output signal was plotted as a function of storage time to estimate shelf-life of chilled pork stored at different temperatures. Partial least squares regression (PLS-regression) was employed to analyze correlation between electronic nose output signal and sensory evaluation score of volatile odor of chilled pork stored at 4 or 20 ℃. Results showed that there was a significant difference in volatile odor of chilled pork stored for different time at -18, 0, 4, 10 or 20 ℃. Higher storage temperature resulted in earlier occurrence of significant decrease of freshness. The shelf-life of chilled pork stored at the above temperatures was 336, 180, 72, 48 h and 18 h, respectively. The correlation coefficients between electronic nose output signal and sensory evaluation score of volatile odor of chilled pork stored at 4 and 20 ℃ were as high as 0.9982 and 0.9998, respectively, demonstrating that electronic nose is a reliable alternative to sensory evaluation for analysis of volatile odor of chilled pork. Electronic nose sensors TA/2, T40/1, T40/2, P30/2, P40/1, P10/2 and P10/1 were all found to give excellent specific responses to various characteristic odors of pork.
Keywords:electronic nose  chilled pork  volatile odor  freshness  shelf-life  
本文献已被 CNKI 等数据库收录!
点击此处可从《食品科学》浏览原始摘要信息
点击此处可从《食品科学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号