首页 | 本学科首页   官方微博 | 高级检索  
     

换热器管板孔腐蚀失效分析
引用本文:李红燕. 换热器管板孔腐蚀失效分析[J]. 全面腐蚀控制, 2013, 0(12): 86-88
作者姓名:李红燕
作者单位:上海赛科石化股份有限责任公司,上海201507
摘    要:某换热器管板孔发生局部减薄并导致换热管出现了穿孔泄漏失效。通过对管板套管失效的宏观分析和微观分析以及腐蚀产物分析,确定管板套管腐蚀与管孔内的硫铵堵塞物有关。硫铵积聚在管板口分解导致管板孔套管腐蚀减薄。通过改进硫铵的喷头结构避免管板孔的硫铵堵塞而解决了管板孔套管失效问题。

关 键 词:换热器管板  腐蚀  硫铵

Analysis on Corrosion of Heat Exchanger Tube-plate Holes
LI Hong-yan. Analysis on Corrosion of Heat Exchanger Tube-plate Holes[J]. Total Corrosion Control, 2013, 0(12): 86-88
Authors:LI Hong-yan
Affiliation:LI Hong-yan (Shanghai Secco Petrochemical Co., Ltd. Shanghai 201507, China)
Abstract:The corrosion occurred on the holes of heat exchanger tube-plate. According to the analysis on the visual and micro morphology and corrosion products, the corrosion of the plate holes was caused by the decomposing of thiamine which was blocked inside the tube-plate holes. The improvement of the shower heads of the thiamine was adopted which can prevent from the block of thiamine inside the hoes of tube-plate.
Keywords:heat exchanger tube-plate  corrosion  thiamine