摘    要:针对煤矿主井车房主提升直流电机接地故障,探究如何能以最小代价取得最好的处理效果。通过研究分析,采用对主井电机故障定子结果进行绝缘检测判断、分析,来确定故障点的确切位置,并最终使得故障得到顺利解决。

关 键 词:摇表  绝缘阻值  换向绕组  青稞纸  绝缘管长度  底座高度

Main Hoist Direct Current Machine Ground Fault Analysis and Processing
GUO Yun-fei.Main Hoist Direct Current Machine Ground Fault Analysis and Processing[J].Hebei Chemical Engineering and Industry,2013(6):100-101,156.
Authors:GUO Yun-fei
Affiliation:GUO Yun-fei ( Xingdong Mine, Jizhong Energy Corporation Ltd., Xingtai 054000, China )
Abstract:Based on the main shaft of coal mine car owners ascending earth fault in direct current motor, how to achieve the best treatment effect with the minimum cost was explored. Through research and analysis, the fault of main shaft motor stator insulation test judgment and analysis were made to determine the location of the point of failure, which eventually got problem be solved smoothly.
Keywords:shaking table  Insulation resistance  reversing winding  highland barley paper  Insulating tube length  base height