首页 | 本学科首页   官方微博 | 高级检索  
     


The Monte Carlo code CEARCPG for coincidence prompt gamma-ray neutron activation analysis
Authors:Xiaogang Han
Affiliation:Center for Engineering Applications of Radioisotopes (CEAR), North Carolina State University, Raleigh, NC 27695-7909, United States
Abstract:Prompt gamma-ray neutron activation analysis (PGNAA) is widely used to determine the elemental composition of bulk samples. The detection sensitivities of PGNAA are often restricted by the inherent poor signal-to-noise ratio (SNR). There are many sources of noise (background) including the natural background, neutron activation of the detector, gamma-rays associated with the neutron source and prompt gamma-rays from the structural materials of the analyzer. Results of the prompt gamma-ray coincidence technique show that it could greatly improve the SNR by removing almost all of the background interferences. The first specific Monte Carlo code (CEARCPG) for coincidence PGNAA has been developed at the Center for Engineering Application of Radioisotopes (CEAR) to explore the capabilities of this technique. Benchmark bulk sample experiments have been performed with coal, sulfur, and mercury samples and indicate that the code is accurate and will be very useful in the design of coincidence PGNAA devices.
Keywords:87.66.&minus  a   24.10.Lx
本文献已被 ScienceDirect 等数据库收录!