摘    要:为了获得过热器和再热器T型三通对集箱静压分布及三通两侧分流比对涡流区和集箱静压分布的影响规律,以空气为工质对纯三通模型进行流动特性试验.研究结果表明:带三通集箱静压分布受一次涡流和二次涡流的共同影响,一次涡流影响范围为-2.5D~2.5D(D为等径三通内径),二次涡流影响范围为-1.5D~1.5D;三通两侧分流比对涡流区范围影响较小;随着三通某侧流量增大,该侧静压降低,但静压分布规律无明显变化.在一次涡流影响范围内,正母线和右下40°线的静压差异受分流比的变化影响较小;侧母线的静压差异随分流比的增大而有所增大.

关 键 词:T型三通  集箱  静压分布  涡流区
收稿时间:2014/9/24 0:00:00

Experimental study on the static pressure distribution in the header with T-joint of boiler superheater and reheater
ZENG Xianyu,YUAN Yichao,XU Guopeng and YAN Shaobing.Experimental study on the static pressure distribution in the header with T-joint of boiler superheater and reheater[J].Energy Research and Information,2016,32(2):96-99.
Authors:ZENG Xianyu  YUAN Yichao  XU Guopeng and YAN Shaobing
Affiliation:School of Energy and Power Engineering/Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China,School of Energy and Power Engineering/Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China,School of Energy and Power Engineering/Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China and School of Energy and Power Engineering/Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
Abstract:Experimental study on the flow characteristics of T-joint model using air as working fluid were conducted to get the influence of T-joint on the static pressure distribution in the header of boiler superheater and reheater as well as the influence of split ratio on the both sides of T-joint on the vortex zone and static pressure distribution. The results showed that the static pressure distribution in T-joint was affected by the first vortex and second vortex. The range affected by the first vortex was from -2.5 to 2.5 times inner diameter of T-joint. The range affected by the second vortex was from -1.5 to 1.5 times inner diameter of T-joint. The split ratio on both sides of T-joint had little effect on the range of vortex. As the flow rate increased on one side of T-joint,the static pressure on this side decreased. However,there was no significant changes of static pressure distribution. In the range affected by the first vortex,the split ratio had little impact on the static pressure difference at the position of positive generatrix and at lower right line of 40 degrees,while the static pressure difference at the position of side generatrix increased with the rising of split ratio.
Keywords:T-joint  header  static pressure distribution  vortex
本文献已被 CNKI 等数据库收录!
点击此处可从《能源研究与信息》浏览原始摘要信息
点击此处可从《能源研究与信息》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号