摘    要:通过对甲醇/水分离塔进料泵运行过程中出现的现象以及热再生塔的结构进行分析,查找甲醇/水分离塔进料泵打量不足的原因。通过对存在问题的整改,甲醇/水分离塔进料泵打量不足的问题得到彻底解决。

关 键 词:甲醇  水分离塔  进料泵  打量  处理、

The cause analysis and treatment to the insufficient feeding quality of feed pump of methanol/water separating tower
LOU Lun-wu , HE Jia-li , MEI Shen.The cause analysis and treatment to the insufficient feeding quality of feed pump of methanol/water separating tower[J].Guizhou Chemical Industry,2013,38(3):60-62.
Authors:LOU Lun-wu  HE Jia-li  MEI Shen
Affiliation:Shen(Guizhou Jinchi Chemical Industry Co Ltd,Tongzi,Guizhou 563200,China)
Abstract:As the phenomenon in running process of methanol/water separating tower' s feed pump and the structure of heat -regenerating tower was analyzed, the cause of the insufficient feeding quality of methanol/water separating tower' s feed pump was searched. The problem of the insufficient feeding quality of methanol/water separating tower's feed pump was completely solved, as to reform the existing problem.