首页 | 本学科首页   官方微博 | 高级检索  
     

连铸板坯二冷高温区传热均匀性研究与优化
引用本文:潘文峰,蔡兆镇,王少波,朱苗勇. 连铸板坯二冷高温区传热均匀性研究与优化[J]. 中国冶金, 2021, 31(8): 23-34. DOI: 10.13228/j.boyuan.issn1006-9356.20210065
作者姓名:潘文峰  蔡兆镇  王少波  朱苗勇
作者单位:东北大学冶金学院, 辽宁 沈阳 110819
基金项目:国家自然科学基金资助项目(51774075,51404061)
摘    要:在板坯连铸过程中,二冷区传热的均匀性对铸坯表面与内部质量均有重要的影响.首先对国内某钢厂二冷各区的喷嘴进行了喷淋性能测试,根据各冷却区喷嘴的布局及2 000 mm×250 mm断面包晶桥梁钢板坯连铸生产过程的各区水量分布,建立了铸坯三维凝固传热有限元计算模型,模拟分析了铸坯在二冷区内的动态凝固传热行为.在此基础上,优化...

关 键 词:板坯连铸  二冷凝固传热  喷嘴布置  均匀性  数值模拟

Study and optimization of uniformity of continuous casting slab heat transfer in high temperature zones of secondary cooling
PAN Wen-feng,CAI Zhao-zhen,WANG Shao-bo,ZHU Miao-yong. Study and optimization of uniformity of continuous casting slab heat transfer in high temperature zones of secondary cooling[J]. China Metallurgy, 2021, 31(8): 23-34. DOI: 10.13228/j.boyuan.issn1006-9356.20210065
Authors:PAN Wen-feng  CAI Zhao-zhen  WANG Shao-bo  ZHU Miao-yong
Affiliation:School of Metallurgy, Northeastern University, Shenyang 110819, Liaoning, China
Abstract:In the practical slab continuous casting, the uniformity of slab heat transfer in the secondary cooling has an important effect on the surface and internal quality of slab. Firstly, the spray parameters of the nozzles in different cooling zones a steel plant was tested, and a 3D heat transfer finite element model of a slab with 2 000 mm×250 mm section was established according to the layout of the nozzles and the corresponding water amount in each cooling zone for casting bridge steel, simulating and analyzing the dynamic heat transfer behavior of the slab in the secondary cooling zones. Base on these, optimized and adjusted the nozzle layout in the secondary cooling high temperature zones. The results show that the transverse surface temperature of the slab in the high temperature zone fluctuates greatly under the conditions of nozzle layout in the original secondary cold zone of a steel plant. Typical production process, the highest temperature of 1 073 ℃ of slab surface forms at the position of 313 mm away from the corner, the lowest temperature of 996 ℃ forms at 873 mm away from the corner in the exit of No.4 cooling zone, the difference value of the temperature reaches 77 ℃. When the slab enters the arc cooling zones, the transverse surface temperature distribution tends to be uniform gradually. Increasing the installation height of the nozzles of No.2 cooling zone from 170 to 200 mm and the height of the nozzles of No.3 and No.4 cooling zone from 200 to 240 mm from the slab surface, the maximum temperature difference of the slab surface in the high temperature zone would reduce to below 30 ℃. The uniformity of slab surface temperature may greatly improve.
Keywords:slab continuous casting  secondary cooling heat transfer and solidification  nozzle layout  uniformity  numerical simulation   