首页 | 本学科首页   官方微博 | 高级检索  
     


An improved “charge pump” electronic ballast with lowTHD and low crest factor
Authors:Chen  W Lee  FC Yamauchi  T
Affiliation:Dept. of Electr. Eng., Virginia Polytech. Inst. & State Univ., Blacksburg, VA;
Abstract:The “charge pump” electronic ballast circuit, which employs a charging capacitor and a high-frequency AC source to implement power factor correction (PFC), has become an attractive topology for ballasting fluorescent lamps. However, the basic “charge pump” electronic ballast circuit has the problems of high total harmonic distortion (THD) of the input current and high crest factor (CF) of the lamp current. This paper analyzes the origin of the problems and proposes a novel solution. With the addition of two small clamping diodes, good input current (PF>0.99, THD<5%) and lamp current (CF<1.6) can be obtained with open-loop control. Experimental results are provided for verification
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏