首页 | 本学科首页   官方微博 | 高级检索  
     


Parametric study of various configurations of hybrid PV/thermal air collector: Experimental validation of theoretical model
Authors:Arvind Tiwari  MS Sodha
Affiliation:aCenter for Energy Studies, Indian Institute of Technology, New Delhi 11 0016, India
Abstract:In this paper, an attempt has been made to evaluate the overall performance of hybrid PV/thermal (PV/T) air collector. The different configurations of hybrid air collectors which are considered as unglazed and glazed PV/T air heaters, with and without tedlar. Analytical expressions for the temperatures of solar cells, back surface of the module, outlet air and the rate of extraction of useful thermal energy from hybrid PV/T air collectors have been derived. Further an analytical expression similar to Hottel–Whiller–Bliss (HWB) equation for flat plate collector has also been derived in terms of design and climatic parameters. Numerical computations have been carried out for composite climate of New Delhi and the results for different configurations have been compared. The thermal model for unglazed PV/T air heating system has also been validated experimentally for summer climatic conditions. It is observed that glazed hybrid PV/T without tedlar gives the best performance.
Keywords:Hybrid PV/thermal  Air heating systems and solar energy
本文献已被 ScienceDirect 等数据库收录!