摘    要:通过分析宁海电厂5、6号锅炉T23水冷壁泄漏情况,提出了在基建调试期间采取的各项应对措施,并在锅炉水冷壁刚性附件结构设计、制造及T23水冷壁安装工艺等方面提出建议,为同类型锅炉提供借鉴。

关 键 词:T23  泄漏  分析  措施

Analysis and Countermeasures of T23 Water Wall Leakage in Tower Type Boiler
GU Hong-wei,GAO Jin-yao.Analysis and Countermeasures of T23 Water Wall Leakage in Tower Type Boiler[J].Zhejiang Electric Power,2010,29(8):37-40.
Authors:GU Hong-wei  GAO Jin-yao
Affiliation:(Zhejiang Guohua Zheneng Power Generation Co., Ltd, Ningbo Zhejiang 315612, China)
Abstract:This paper analyzes of the T23 water walt leakage of No.5 and No.6 Boilers in Ninghai Power Plant, puts forward various countermeasures during capital construction and comissioning period and make suggestions on the aspects of the structure design and manufacturing of the rigid aecessories of the boiler water wall, installation technology of T23 water wall etc. to offer a reference for the same type of boilers.